Be sure to reset the Filter counter after cleaning or replacing
the filters.
Resetting the Filter Counter
Maintenance and Cleaning
Turn off the projector, and unplug the AC power cord
from the AC outlet.
Turn the projector over and remove the filters by pulling
the latches upward.
1
2
Filters prevents dust from accumulating on the optical elements inside the projector. Should the filters become
clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat buildup
and adversely affect the life of the projector. If a “Filter warning” icon appears on the screen, clean the filters
immediately. Clean the filter by following the steps below.
Gently clean the filters by using a brush or rinse them
softly.
3
When rinsing the filters, dry them well. Replace the
filters properly. Make sure that the filters are fully
inserted to the projector.
4
CAUTION
Do not operate the projector with the filters
removed. Dust may accumulate on the optical
elements degrading picture quality.
Do not put anything into the air vents. Doing so
may result in malfunction of the projector.
RECOMMENDATION
We recommend avoiding dusty/smoky environments
when you operate the projector. Usage in these
environments may cause poor image quality.
When using the projector under dusty or smoky conditions,
dust may accumulate on a lens, LCD panels, or optical
elements inside the projector degrading the quality of a
projected image. When the symptoms above are noticed,
contact your authorized dealer or service station for proper
cleaning.
Note:
When reinserting these filters, be sure
that the slit part is facing the outer side.
Filters
Pull up and remove.
Cleaning the Filters
Press the MENU button to display the On-Screen
Menu. Use the Point ▲▼ buttons to select Setting and
then press the Point or the SELECT button.
Use the Point ▲▼ buttons to select Filter counter
and then press the SELECT button. Use the Point ▲▼
buttons to select Filter counter reset and then press
the SELECT button. Filter counter Reset? appears.
Select Yes to continue.
1
2
Filter counter
Filter counter Reset?
appears.
Select Yes, then another
confirmation box appears.
Select Yes again to reset
the Filter counter.
Another confirmation dialog box appears, select Yes to
reset the Filter counter.