Chapter 6 Basic setting and operation
"When PJ lamp is off" signifies the lamp goes out without user operation. "When PJ is turned into Standby in proper user
operation" signifies that the projector is turned on by using the web browser and then it is turned into standby with ON/
STANDBY button on the top control or the remote control.
Up to 99,999 hours can be set for the time setting.
If condition "When Auto Play is failed" is checked, the trap is sent when the error occurs during the auto display
operation using with the network viewer function (+p.113). For further information of the error, refer to item "Auto
Display setting and control page [3]"((+p.127).
Trap option
Trap option setting
Tick the check boxes in front of the condition item to send the trap.
Click Set button if you tick or un-tick the check box on a page.
[1]––––––––––––––––––––––––––––––––––
o When PJ lamp is off.
o When PJ lamp replacement time is reached.
o When PJ needs service.
o When internal PJ temperature is too high.
[2]––––––––––––––––––––––––––––––––––
o When PJ is turned into Standby in proper user
operation.
o When accumulated filter use time
reaches [ ] hours.
o When Power management function turns PJ
lamp off.
[3]––––––––––––––––––––––––––––––––––
o When the signal is interrupted.
o When Auto Play is failed.
o When lamp Corres. Value
reaches [ ] hours.