LC-W4 Basic Serial Command Functional Specifications
22/25
7.10 Status 2 Read Command
COMMAND “CRA” [CR]
Detail Get the operating status of Video Mute & Volume Mute
Acceptable “%1” [CR]
%
Return hexadecimal digit of 1 byte as a two-figure character
line. Hexadecimal digit is regarded as eight bits and each bit is
defined as below:
+ + + + + + + +
Bit 0: No Show ON=1/OFF=0
(ON =1, OFF =0)
Bit 1: Mute ON=1/OFF=0
(ON =1, OFF =0)
Bit 2: Spare
Bit 3: Spare
Bit 4: Spare
Bit 5: Spare
Bit 6: Spare
Bit 7: There is a signal / no signal
(No signal =1, Signal =0)
Example:
1) When No Show is ON: ++++ +++1
Sound Mute ON: ++++ ++11 ĺ “03”
Sound Mute OFF: ++++ ++01 ĺ “01”
There is no signal: 1+++ +++1 ĺ “81”
2) When No Show is OFF: ++++ +++0
Sound Mute ON: ++++ ++10 ĺ “02”
Sound Mute OFF: ++++ ++00 ĺ “00”
There is no signal: 1+++ +++0 ĺ “80”
When it is in Standby mode or processing Cooling Down, it
returns “FF” [CR] [LF] in spite of the conditions above.