LC-W4 Basic Serial Command Functional Specifications
20/25
7.4 Input Mode Read Command
COMMAND “CR1” [CR]
Detail Get selected Input
Acceptable Acceptable
%1
“1” = Input 1 is selected
“2” = Input 2 is selected
“3” = Input 3 is selected
Response
Unacceptable “?” [CR]
7.5 Lamp Time Read Command
COMMAND “CR3” [CR]
Detail Get total lamp running hours
Acceptable “%1%2” [CR]
%1, %2
There is lamp 1 data, once space, and lamp 2 data.
%1 = lamp No.1
%2 = lamp No.2
Ex: “04100410” [CR]
ƒƒƒƒ ĺ Lamp No.1 = 410 Hours
Lamp No.2 = 410 Hours
Response
Unacceptable “?” [CR]
7.6 Setting Read Command
COMMAND “CR4” [CR]
Detail Get screen setting status such as Ceiling/Rear
Acceptable “%1” [CR]
%1
“11” [CR] = Normal Screen Setting
“10” [CR] = Picture is top/bottom reversed
(Status: Rear & Ceiling ON)
“01” [CR] = Picture is left/right reversed (Status: Rear ON)
“00” [CR] = Picture is top/bottom and left/right reversed
(Status: Ceiling ON
)
Response
Unacceptable “?” [CR]