APPENDIX
LAMP REPLACEMENT
LAMP REPLACE
When the life of Projection Lamp of this projector draws to an end,
LAMP REPLACE indicator lights yellow. If this indicator lights yellow,
replace the projection lamp with a new one promptly.
ORDER REPLACEMENT LAMP
Replacement Lamp can be ordered through your dealer. When ordering a Projection Lamp, give the
following information to the dealer.
Model No. of your projector : LC-SM4
Replacement Lamp Type No. : POA-LMP37
(Service Parts No. 610 295 5712)
For continued safety, replace with a lamp assembly of
the same type.
Do not drop a lamp assembly or touch a glass bulb! The
glass can shatter and may cause injury.
Allow a projector to cool, for at least 45 minutes before
you open Lamp Cover. The inside of a projector can
become very hot.
WARNING
TEMP .
LAMP
REPLACE
TOP CONTROL
CAUTION
Turn off the projector and disconnect AC plug. Allow the
projector to cool at least for 45 minutes.
Remove 2 screws with a screwdriver and pull out Lamp
Assembly by grasping Handle.
1
3
Replace Lamp Assembly with a new one and tighten 2 screws
back into position. Make sure that Lamp Assembly is set
properly. Replace Lamp Cover and tighten the screw.
4
To remove Lamp Cover, remove the screw with a screwdriver .
2
Connect the AC Power Cord to the projector and turn on the
projector.
6
Follow these steps to replace the lamp assembly.
Reset the Lamp Replace Counter.
Refer to LAMP REPLACE COUNTER on the next page .
5
LAMP
ASSEMBLY
HANDLE
LAMP COVER
NOTE : Do not reset Lamp Replace Counter when Projection
Lamp is not replaced.
This indicator lights yellow
when the life of the projection
lamp draws to an end.
Replace the Projection Lamp
with a new one promptly.
SCREW